Review





Similar Products

86
Oxford Metrics optical motion capture system
Optical Motion Capture System, supplied by Oxford Metrics, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/optical+motion+capture+system/nexus+software+vicon/10__3390_slash_bioengineering13060650-82-10-17
Average 86 stars, based on 1 article reviews
optical motion capture system - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

86
Oxford Metrics eight camera optical motion capture system
Eight Camera Optical Motion Capture System, supplied by Oxford Metrics, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/optical+motion+capture+system/10+camera+capture+motion+system/pmc13112202-64-7-13
Average 86 stars, based on 1 article reviews
eight camera optical motion capture system - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

86
Oxford Metrics 9 camera optical motion capture system
9 Camera Optical Motion Capture System, supplied by Oxford Metrics, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/optical+motion+capture+system/10+camera+capture+motion+system/pm41934762-66-3-9
Average 86 stars, based on 1 article reviews
9 camera optical motion capture system - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

86
Leyard Optoelectronic optical motion capture system
Optical Motion Capture System, supplied by Leyard Optoelectronic, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/optical+motion+capture+system/capture+motion+software/pm41922587-142-2-1
Average 86 stars, based on 1 article reviews
optical motion capture system - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

86
Oxford Metrics vicon optical motion capture system
The absolute change in kinematics and ligament elongation outputs acquired from the <t>Vicon</t> optical motion capture system <t>(motion</t> <t>tracking</t> system = reference) and Next-AR navigation platform. ( A ) Valgus angle (°) and ( B ) corresponding MCL elongation (mm) during the valgus stress test are shown. Additionally, ( C ) varus angle (°) and ( D ) corresponding LCL elongation (mm) during the varus stress test are displayed. The box plots exhibit minimum, median, interquartile range (25th and 75th percentile), outliers (circle), and total range. The kinematics and ligament elongations obtained from Next-AR and reference were statistically compared using a linear mixed model for the data without outliers and a robust linear mixed model for the data with outliers ( p < 0.05)
Vicon Optical Motion Capture System, supplied by Oxford Metrics, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/optical+motion+capture+system/capture+motion+optical+system+vicon/pmc13032992-120-7-21
Average 86 stars, based on 1 article reviews
vicon optical motion capture system - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

86
Oxford Metrics 10 camera passive optical motion capture system
The absolute change in kinematics and ligament elongation outputs acquired from the <t>Vicon</t> optical motion capture system <t>(motion</t> <t>tracking</t> system = reference) and Next-AR navigation platform. ( A ) Valgus angle (°) and ( B ) corresponding MCL elongation (mm) during the valgus stress test are shown. Additionally, ( C ) varus angle (°) and ( D ) corresponding LCL elongation (mm) during the varus stress test are displayed. The box plots exhibit minimum, median, interquartile range (25th and 75th percentile), outliers (circle), and total range. The kinematics and ligament elongations obtained from Next-AR and reference were statistically compared using a linear mixed model for the data without outliers and a robust linear mixed model for the data with outliers ( p < 0.05)
10 Camera Passive Optical Motion Capture System, supplied by Oxford Metrics, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/optical+motion+capture+system/10+camera+capture+motion+system/pm41887112-81-9-15
Average 86 stars, based on 1 article reviews
10 camera passive optical motion capture system - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

86
Oxford Metrics ten camera optical motion capture system
The absolute change in kinematics and ligament elongation outputs acquired from the <t>Vicon</t> optical motion capture system <t>(motion</t> <t>tracking</t> system = reference) and Next-AR navigation platform. ( A ) Valgus angle (°) and ( B ) corresponding MCL elongation (mm) during the valgus stress test are shown. Additionally, ( C ) varus angle (°) and ( D ) corresponding LCL elongation (mm) during the varus stress test are displayed. The box plots exhibit minimum, median, interquartile range (25th and 75th percentile), outliers (circle), and total range. The kinematics and ligament elongations obtained from Next-AR and reference were statistically compared using a linear mixed model for the data without outliers and a robust linear mixed model for the data with outliers ( p < 0.05)
Ten Camera Optical Motion Capture System, supplied by Oxford Metrics, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/optical+motion+capture+system/10+camera+capture+motion+system/pm41845144-80-7-14
Average 86 stars, based on 1 article reviews
ten camera optical motion capture system - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

Image Search Results


The absolute change in kinematics and ligament elongation outputs acquired from the Vicon optical motion capture system (motion tracking system = reference) and Next-AR navigation platform. ( A ) Valgus angle (°) and ( B ) corresponding MCL elongation (mm) during the valgus stress test are shown. Additionally, ( C ) varus angle (°) and ( D ) corresponding LCL elongation (mm) during the varus stress test are displayed. The box plots exhibit minimum, median, interquartile range (25th and 75th percentile), outliers (circle), and total range. The kinematics and ligament elongations obtained from Next-AR and reference were statistically compared using a linear mixed model for the data without outliers and a robust linear mixed model for the data with outliers ( p < 0.05)

Journal: Archives of Orthopaedic and Trauma Surgery

Article Title: Concurrent validation of a novel intraoperative navigation platform for total knee arthroplasty

doi: 10.1007/s00402-026-06265-9

Figure Lengend Snippet: The absolute change in kinematics and ligament elongation outputs acquired from the Vicon optical motion capture system (motion tracking system = reference) and Next-AR navigation platform. ( A ) Valgus angle (°) and ( B ) corresponding MCL elongation (mm) during the valgus stress test are shown. Additionally, ( C ) varus angle (°) and ( D ) corresponding LCL elongation (mm) during the varus stress test are displayed. The box plots exhibit minimum, median, interquartile range (25th and 75th percentile), outliers (circle), and total range. The kinematics and ligament elongations obtained from Next-AR and reference were statistically compared using a linear mixed model for the data without outliers and a robust linear mixed model for the data with outliers ( p < 0.05)

Article Snippet: The retro-reflective marker trajectories captured with the Vicon optical motion capture system were processed using dedicated motion tracking software (Nexus 2.9, Vicon, Oxford, UK).

Techniques:

Comparison of kinematics output acquired from the Vicon optical motion capture system (motion tracking system = reference) and Next-AR navigation platform: ( A ) Knee flexion (°), ( B ) valgus angle (°), and ( C ) tibial internal rotation (°), MCL elongation (mm), and LCL elongation (mm). The box plots exhibit minimum, median, interquartile range (between the 25th and 75th percentile), maximum range, and outliers (circle). The kinematics obtained from the kinematics obtained from Next-AR and reference were statistically compared using a linear mixed model for the data without outliers and a robust linear mixed model for the data with outliers ( p < 0.05.) Asterix indicates a statistical difference

Journal: Archives of Orthopaedic and Trauma Surgery

Article Title: Concurrent validation of a novel intraoperative navigation platform for total knee arthroplasty

doi: 10.1007/s00402-026-06265-9

Figure Lengend Snippet: Comparison of kinematics output acquired from the Vicon optical motion capture system (motion tracking system = reference) and Next-AR navigation platform: ( A ) Knee flexion (°), ( B ) valgus angle (°), and ( C ) tibial internal rotation (°), MCL elongation (mm), and LCL elongation (mm). The box plots exhibit minimum, median, interquartile range (between the 25th and 75th percentile), maximum range, and outliers (circle). The kinematics obtained from the kinematics obtained from Next-AR and reference were statistically compared using a linear mixed model for the data without outliers and a robust linear mixed model for the data with outliers ( p < 0.05.) Asterix indicates a statistical difference

Article Snippet: The retro-reflective marker trajectories captured with the Vicon optical motion capture system were processed using dedicated motion tracking software (Nexus 2.9, Vicon, Oxford, UK).

Techniques: Comparison